公司基本資料信息
|
B?HLER NiMo 1-IG伯樂(lè)焊絲
Description
Copper coated GMAW wire for high strength, quenched and tempered fine-grained construc-
tional steels.
The wire is suited for joint welding in boiler, pressure vessel, pipeline, and crane construction
as well as in structural steel engineering. The typical composition of the wire fulfils the require-
ments of the NORSOK-regulation for ?water injection systems“.
Due to the precise addition of micro alloying elements NiMo1-IG wire features excellent ductility
and crack resistance in spite of its high strength. Good cryogenic impact energy down to -60 °C,
low hydrogen contents in the deposit, best feedability and low copper contents are other
advantages of this wire.
Approvals and Certificates
DB (42.014.06), üZ (42.014/4), ?BB, GL (4Y56S), UDT, SEPROZ
base Materials
pipe steels and fine grained steels, quenched and tempered fine-grained steels
S380N - S500N, S380NL - S500NL, S500NC - S550NC, N-A-XTRA 56-70, BHV 70,
PAS 600, HSM 600, 20MnMoNi5-5
ASTM A517 Gr. A, B, C, E, F, H, J, K, M, P; A225 Gr. C; A633 Gr. E; A572 Gr. 65
API-spec 5L: X70, X80
Operating Data
shielding gases: Argon + 15 - 25 % CO 2 ? mm
Argon + 0 - 5 % CO 2 + 3 - 10 % O 2 (0.9)
100 % CO 2 1.0
1.2
Preheating and interpass temperature as required by the base metal.
Mechanical Properties of All-weld metal
(*) u u2
yield strength R e N/mm 2 : 620 (≥ 550) 590 (≥ 550)
tensile strength R m N/mm 2 : 700 (650 - 800) 680 (620 - 770)
elongation A (L 0 = 5d 0 ) %: 23 (≥ 320) 22 (≥ 320)
impact work ISO-V KV J + 20 °C: 140 (≥ 120) 120 (≥ 100)
- 40 °C: 110 (≥ 390) (≥ 347)
- 60 °C: (≥ 347)
(*) u untreated, as-welded – shielding gas Ar + 15 - 25 % CO 2
u2 untreated, as-welded – shielding gas 100 % CO 2
Typical Composition of Solid Wire
C Si Mn Mo Ni
wt-% 0.08 0.6 1.8 0.3 0.9